Digital Repository

The ParaSightT-F dipstick test as a routine diagnostic tool for malaria in Sri Lanka

Show simple item record

dc.contributor.author Kodisinghe, H.M. en_US
dc.contributor.author Perera, K.L.R.L. en_US
dc.contributor.author Premawansa, S. en_US
dc.contributor.author Naotunne, T. de S. en_US
dc.contributor.author Wickremasinghe, A.R. en_US
dc.contributor.author Mendis, K.N. en_US
dc.date.accessioned 2014-10-29T09:15:13Z
dc.date.available 2014-10-29T09:15:13Z
dc.date.issued 1997 en_US
dc.identifier.citation Transactions of the Royal Society of Tropical Medicine and Hygiene. 1997; 91(4): pp.398-402 en_US
dc.identifier.issn 0035-9203 (Print) en_US
dc.identifier.issn 1878-3503 (Electronic) en_US
dc.identifier.uri http://repository.kln.ac.lk/handle/123456789/1326
dc.description Indexed in MEDLINE
dc.description.abstract Blood from 1053 persons who presented for treatment at outpatient clinics of government health institutions in Sri Lanka, and 250 who took part in a blood survey for malaria, was examined by thick blood film microscopy under routine field conditions, and by the ParaSight-F dipstick method. All the samples were also examined microscopically under laboratory conditions when 4 times the number of microscope fields were examined. Compared with this reference standard, the sensitivity and specificity of the ParaSight-F test were 90.2% and 99.1%, and those of microscopy in the field were 92.4% and 98.4% respectively, there being no statistically significant difference between the 2 methods. The ParaSight-F test reading correlated significantly and positively with the intensity of clinical disease of patients but not with their peripheral parasitaemia, indicating that it may be a more accurate measure of the true parasite load than microscopy, which detects only parasites which are in the peripheral blood and not those which are sequestered in deep organs. The ParaSight-F test, however, failed to detect Plasmodium falciparum infections with only gametocytes in the blood (19.6% of the infected blood samples in this study). The time taken for a patient to revert to negativity by the ParaSight-F test was also significantly longer, up to 14 d. This would make the test unsuitable for checking the response to antimalarial treatment within 14 d. In an endemic area it would therefore fail to detect drug resistant populations of parasites.
dc.publisher Oxford University Press en_US
dc.subject Malaria en_US
dc.subject Malaria-diagnosis en_US
dc.subject Antigens, Protozoan-analysis
dc.subject Antimalarials-therapeutic use
dc.subject Chloroquine-therapeutic use
dc.subject Malaria, Falciparum-diagnosis
dc.subject Malaria, Falciparum-drug therapy
dc.subject Plasmodium falciparum-immunology
dc.subject Protozoan Proteins-blood
dc.subject Reagent Strips
dc.title The ParaSightT-F dipstick test as a routine diagnostic tool for malaria in Sri Lanka en_US
dc.type Article en_US
dc.identifier.department Public Health en_US
dc.creator.corporateauthor Royal Society of Tropical Medicine and Hygiene en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account