Medicine

Permanent URI for this communityhttp://repository.kln.ac.lk/handle/123456789/12

This repository contains the published and unpublished research of the Faculty of Medicine by the staff members of the faculty

Browse

Search Results

Now showing 1 - 3 of 3
  • Thumbnail Image
    Item
    Comparison of four low-cost carbapenemase detection tests and a proposal of an algorithm for early detection of carbapenemase-producing Enterobacteriaceae in resource-limited settings
    (Public Library of Science, 2021) Kumudunie, W.G.M.; Wijesooriya, L.I.; Wijayasinghe, Y.S.
    ABSTRACT: Rapidly progressing antibiotic resistance is a great challenge in therapy. In particular, the infections caused by carbapenem-resistant Enterobacteriaceae (CRE) are exceedingly difficult to treat. Carbapenemase production is the predominant mechanism of resistance in CRE. Early and accurate identification of carbapenemase-producing carbapenem-resistant Enterobacteriaceae (CP-CRE) is extremely important for the treatment and prevention of such infections. In the present study, four phenotypic carbapenemase detection tests were compared and an algorithm was developed for rapid and cost-effective identification of CP-CRE. A total of 117 Enterobacteriaceae (54 CP-CRE, 3 non-CP-CRE, and 60 non-CRE) isolates were tested for carbapenemase production using modified Hodge test (MHT), modified carbapenem inactivation method (mCIM), Carba NP test (CNPt), and CNPt-direct test. The overall sensitivity/specificity values were 90.7%/92.1% for MHT, 100%/100% for mCIM, 75.9%/100% for CNPt, and 83.3%/100% for CNPt-direct. OXA-48-like enzymes were detected with 93.2% sensitivity by MHT and >77.3% sensitivity by two Carba NP tests. MHT could only detect half of the NDM carbapenemase producers. CNPt-direct exhibited enhanced sensitivity compared to CNPt (100% vs 25%) for detection of NDM producers. Considering these findings we propose CNPt-direct as the first test followed by mCIM for rapid detection of CP-CRE. With this algorithm >80% of the CP-CRE could be detected within 24 hours from the time the sample is received and 100% CP-CRE could be detected in day two. In conclusion, mCIM was the most sensitive assay for the identification of CP-CRE. CNPt-direct performed better than CNPt. An algorithm consisting CNPt-direct and mCIM allows rapid and reliable detection of carbapenemase production in resource-limited settings.
  • Thumbnail Image
    Item
    Prevalence of asthma and comparison of ventilator capacity of asthmatics (when free of asthma) and non asthmatics among workers in selected garment factories
    (College of the Community Physicians of Sri Lanka, 2009) Abeysena, C.; Jayawardana, P.; Wickramasinha, W.P.K.; Dassanayake, I.S.
    INTRODUCTION: Asthma has been reported to be common among garment factory workers. Objective: To determine the prevalence of asthma and to compare the lung functions among asthmatics and non asthmatics among garment factory workers. METHODS: A descriptive comparison study was conducted among 774 workers of selected garment factories in the Ekala Industiral Area, Ja ela. All workers who have served for a minimum period of one year in the factory were included in the study. An interviewer administered questionnaire was used to assess personal details and presence of wheezing, dysponoea and cough and other relevant data. All those with wheezing and those with presence of both cough and dyspnoea in the absence of wheezing during the past one year were considered as asthmatics. Spirometry was performed using an electronic spirometer. Forced Vital Capacity (FVC), Forced Expiratory Volume in first second of FVC (FEV) and Peak Expiratory Flow Rate (PEFR) were assessed. The ventilatory capacity was compared among asthmatics and non asthmatics using Student T test, Mann Whitney U test or chi-squired test. Results: The prevalence of asthma was 30% (95%CI: 26.7%, 33%). The mean ventilator capacity of asthmatics and non asthmatics respectively were as follows FVC: 2.24 L versus 2.39 L (p<0.05), FEV-i.o: 2.17 L versus 2.37 L (p<0.001), PEFR {geometric mean): 5.87 L/sec versus 7.17 L/sec (p<0.001). The mean difference between the predicted normal values and observed values among asthmatics and non asthmatics were as follows: FVC: 0.53 L versus 0.58 L (p>0.05), FEVro: 0.30 L versus 0.25 L (p>0.05), PEFR (median): 1.21 L/sec versus 0.45 L/sec (p<0.001). Ninety three (40.3%) of asthmatics and 149 (27.5%) non-asthmatics had PEFR <80% of the predicted which was statistically significant (p<0.001). CONCLUSION: Prevalence of asthma was high among garment factory workers. Ventilatory capacity and predicted normal values of asthmatics when free of asthma were affected in comparison to non asthmatics.
  • Thumbnail Image
    Item
    Single dose treatment of mixed helminth infections--a comparison of three different regimes
    (Sri Lanka Medical Association, 1987) de Silva, D.G.H.; Lionel, N.D.; Premaratne, U.N.; Warnasuriya, N.; Soysa, P.E.; Fonseka, P.H.
    No abstract available
All items in this Institutional Repository are protected by copyright, with all rights reserved, unless otherwise indicated. No item in the repository may be reproduced for commercial or resale purposes.