    Investigating Parkinson's disease with dual high resolution pharyngeal manometry with impedance and videofluoroscopy
    (Blackwell Publishing, 2024) Saleem, S.; Miles, A.; Allen, J.
    PURPOSE: To characterize pharyngeal function in people with Parkinson's Disease using both high resolution impedance manometry (HRIM) and videofluoroscopy (VFSS) and to explore correlations between VFSS and HRIM metrics. METHODS: All participants received both VFSS and HRIM within 24 h-time window. A standard VFSS protocol (IDDSI 0: 1 mL, 3 mL, 20 mL, and 100 mL) was performed. A solid-state unidirectional catheter (36 pressure sensors) was used to acquire manometric data for triplicate swallows (IDDSI 0: 5 mL, 10 mL, 20 mL), quantitative swallow analysis was completed through Swallowtail™ and SwallowGateway™. Parameters were compared to published norms and statistical tests explored correlational associations (p < 0.05). RESULTS: Twenty-one participants (76% male; mean age 70 years, SD7.16) with mild-moderate severity PD were recruited with 73% reporting Eating Assessment Tool (EAT-10) scores ≥3 indicating swallow impairment. Compared to normal metrics, one third of participants had abnormally elevated hypopharyngeal contractile integral (HPCI), hypopharyngeal peak pressure, upper esophageal sphincter (UES) integrated relaxation pressure (UES IRP), and reduced UES maximum admittance. Five participants showed compromised swallow safety (Penetration-Aspiration Scale score ≥6). One third of participants had abnormal VFSS values for pharyngoesophageal segment (PES) opening duration, maximum PES opening distance, and maximum hyoid displacement measures. Some HRIM metrics had a strong correlation with pharyngeal VFSS measures (r > 0.60, p < 0.05). CONCLUSION: This study identifies early manometric signs of pharyngeal dysfunction in people with PD. The congruence of the VFSS and HRIM measures confirms the hypothesis of insidious early decline in swallow function in PD despite maintenance of airway safety (i.e., low aspiration rates).
  • Thumbnail Image
    Item
    Developing a protocol for quantitative analysis of liquid swallowing in children.
    (American Speech-Language-Hearing Association, 2022) Miles, A.; Dharmarathna, I.; Fuller, L.; Jardine, M.; Allen, J.
    Purpose: Objective measures in videofluoroscopic swallow studies (VFSSs) can quantify swallow biomechanics. There are a wide array of validated measures studied in infants, children, and adults. There is a need for a pediatric VFSS protocol that consists of a small number of vital, time efficient, and clinically relevant measures. In this study, we aimed to establish a standard protocol for quantitative VFSS analysis in children. Method: Protocol development began with a systematic literature review, which identified 22 quantitative and eight descriptive measures available in the literature. A pediatric VFSS database of 553 children was collected using a standardized VFSS protocol. Studies were evaluated using the 30 previously reported measures covering displacement and timing parameters as well as penetration-aspiration and residue. Measures were tested for rater reliability and internal consistency. Measures meeting acceptable values for protocol inclusion were included in the final protocol (Cronbach's alpha > .53). Results: Interrater and intrarater reliability of 17 measures met acceptable reliability levels. During internal consistency testing, we removed six further measures based on Cronbach's alpha levels indicating that two or more measures were equivalent in measuring the same aspect of swallow biomechanics in children. A VFSS protocol of reliable, valid, and obtainable objective quantitative (n = 6) and descriptive measures (n = 3) with separate protocols for young infants (≤ 9 months) and older children was established. Conclusions: A standardized quantitative VFSS protocol for children has been developed to suit two age groups (≤ 9 and > 9 months old). Consistent VFSS administration and reporting support assessment over time and across disease groups. Future research should focus on how this information can be used by clinicians to produce individualized treatment plans for children with swallowing impairment.
  • Thumbnail Image
    Item
    Quantifying Bolus residue and its risks in children: A videofluoroscopic study
    (American Speech-Language-Hearing Association, 2021) Dharmarathna, I.; Miles, A.; Allen, J.
    ABSTRACT: Purpose Postswallow residue is a clinical sign of swallow impairment and has shown a strong association with aspiration. Videofluoroscopy (videofluoroscopic study of swallowing [VFSS]) is commonly used to visualize oropharyngeal swallowing and to identify pharyngeal residue. However, subjective binary observation (present or absent) fails to provide important information on volume or location and lacks objectivity and reproducibility. Reliable judgment of changes in residue over time and with treatment is therefore challenging. We aimed to (a) determine the reliability of quantifying pharyngeal residue in children using the bolus clearance ratio (BCR), (b) determine associations between BCR and other timing and displacement measures of oropharyngeal swallowing, and (c) explore the association between BCR and penetration-aspiration in children. Method In this single-center retrospective observational study, we obtained a set of quantitative and descriptive VFSS measures from 553 children (0-21 years old) using a standard protocol. VFSS data were recorded at 30 frames per second for quantitative analysis using specialized software. Results Good interrater (ICC = .86, 95% CI [.74, .961], p < .001) and excellent intrarater reliability was achieved for BCR (ICC = .97, 95% CI [.91, 1.000], p = 001). Significant correlations between BCR and pharyngeal constriction ratio and total pharyngeal transit time were reported (p < .05). Using binomial logistic regression modeling, we found BCR was predictive of penetration-aspiration in children, χ2(13) = 58.093, p < .001, 64.9%. Children with BCR of ≥ 0.1 were 4 times more likely to aspirate. Conclusion BCR is a reliable, clinically useful measure to quantify postswallow residue in children, which can be used to identify and treat children with swallow impairments, as well as to measure outcomes of intervention.