Digital Repository

Estimating the unit domestic emission of biological oxygen demand and Escherichia coli in Hanoi, Vietnam.

Show simple item record

dc.contributor.author Kaluarachchi, T. U. N.
dc.contributor.author Masago, Y.
dc.contributor.author Kumar, P.
dc.contributor.author Nga, T.V.
dc.date.accessioned 2017-11-21T08:20:33Z
dc.date.available 2017-11-21T08:20:33Z
dc.date.issued 2017
dc.identifier.citation Kaluarachchi, T. U. N., Masago,Y., Kumar,P., and Nga,T.V. (2017). Estimating the unit domestic emission of biological oxygen demand and Escherichia coli in Hanoi, Vietnam. International Research Symposium on Pure and Applied Sciences, 2017 Faculty of Science, University of Kelaniya, Sri Lanka.p43. en_US
dc.identifier.uri http://repository.kln.ac.lk/handle/123456789/18177
dc.description.abstract Direct discharge of domestic blackwater to urban rivers is a common sight in urbanized areas in developing countries, and many development projects are undergoing to improve such situations to achieve sustainable water environment. To estimate the effect of the sewerage development on urban water environment, along with other influencing factors such as population increase and climate change, a scientific model to simulate water quality of four urban rivers in Hanoi, Vietnam, was developed using the Water Evaluation and Planning (WEAP) software. In estimating concentrations of Biological Oxygen Demand (BOD) and Escherichia coli in the rivers, it is necessary to obtain unit emission rates of these parameters. While Vietnam National standard (TCVN 7958:2008) has proposed a value range (30-35 g/capita/day) for the unit domestic emission for BOD, there is no such value range for E. coli. Moreover, recent studies done in Hanoi showed that the values recommended in TCVN 7958:2008 underrepresent the actual emission, hence the existing wastewater treatment facilities should be redesigned with actual influent wastewater quality for better treatment. Considering the above, this study was conducted to estimate the unit domestic emission of BOD and E. coli in central Hanoi. Different unit emissions of BOD and E. coli were used to simulate BOD and E. coli concentrations in wastewater. These simulated values were compared with the observed concentrations of BOD and E. coli in four waste water rivers in Hanoi in 2009. Least square regression using the simulated values and observed values was performed to get the most suitable unit emission of BOD and E. coli. We found that BOD; 31.12 g/capita/day and E. coli; 2.9 ×1011cfu / 100mL /capita/day, give the closest simulated BOD and E. coli concentrations to the observed BOD and E .coli concentrations in waste water rivers.. en_US
dc.language.iso en en_US
dc.publisher International Research Symposium on Pure and Applied Sciences, 2017 Faculty of Science, University of Kelaniya, Sri Lanka. en_US
dc.subject Biological oxygen demand en_US
dc.subject Escherichia coli en_US
dc.subject Simulation en_US
dc.title Estimating the unit domestic emission of biological oxygen demand and Escherichia coli in Hanoi, Vietnam. en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Advanced Search

Browse

My Account