Please use this identifier to cite or link to this item: http://repository.kln.ac.lk/handle/123456789/1187
Title: Anal sphincter defects. Correlation between endoanal ultrasound and surgery
Authors: Deen, K.I.
Kumar, D.
Williams, J.G.
Olliff, J.
Keighley, M.R.
Keywords: Anal Canal-abnormalities
Anal Canal-surgery
Anal Canal-ultrasonography
Anus Diseases-surgery
Anus Diseases-ultrasonography
Fecal Incontinence-surgery
Predictive Value of Tests
Issue Date: 1993
Publisher: Lippincott Williams and Wilkins
Citation: Annals of Surgery. 1993; 218(2): pp.201-205
Abstract: OBJECTIVE: This study was performed to (1) correlate and sphincter defects, identified by endoanal ultrasound with operative findings, and (2) define the appearance of such sphincter defects as seen at operation. SUMMARY BACKGROUND DATA : Endoanal ultrasonography is a minimally invasive method of imaging the anal sphincter complex and enables identification of anal sphincter defects. Little is known about the accuracy and limitations of endoanal ultrasound in identifying such defects. Furthermore, there are no data about the appearances of these endosonic sphincter defects as seen at operation. METHODS: Forty-four patients (40 women; age range, 26 to 80 years; mean age, 56 years) with fecal incontinence, undergoing pelvic floor repair, were investigated by endoanal ultrasound before operation. Endosonic findings were correlated with the appearances of external anal sphincter, internal anal sphincter, and intersphincteric space, at operation. Diagnosis of the site and type of defect was made by macroscopic appearances. Uncertainty about the type of sphincter defect was resolved by obtaining muscle biopsies for histology. RESULTS: All external sphincter defects seen by endoanal ultrasound (n = 23) were confirmed at operation. Twenty-one of 22 internal sphincterdefects identified by endosonography also were confirmed at operation. In ten patients with a neuropathic anal sphincter complex, the morphology was normal on endosonography, and this was confirmed at operation. (Sensitivity and specificity of 100% for external anal sphincter; 100% and 95.5%, respectively, for internal and sphincter) CONCLUSIONS: These data show that endoanal ultrasound is an accurate method of identifying anal sphincter defects.
Description: Indexed in MEDLINE
URI: http://repository.kln.ac.lk/handle/123456789/1187
ISSN: 0003-4932 (Print)
1528-1140 (Electronic)
Appears in Collections:Journal/Magazine Articles

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.