Please use this identifier to cite or link to this item: http://repository.kln.ac.lk/handle/123456789/11543
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNandasena, Y.L.S.
dc.contributor.authorWickremasinghe, A.R.
dc.contributor.authorLee, K.
dc.contributor.authorSathiakumar, N.
dc.date.accessioned2016-02-02T09:07:27Z
dc.date.available2016-02-02T09:07:27Z
dc.date.issued2009
dc.identifier.citationJournal of the College of Community Physicians of Sri Lanka. 2009;14 (Sup 1): 31en_US
dc.identifier.issn1391-3174
dc.identifier.urihttp://repository.kln.ac.lk/handle/123456789/11543
dc.descriptionOral Presentation Abstract (OP-25), 14th Annual Academic Sessions College of Community Physicians of Sri Lanka, 9th-12th September 2009, Colomboen_US
dc.description.abstractINTRODUCTION: Globally, about five million deaths per year are attributed to tobacco smoke. Secondhand smoke accounts for a substantial proportion of these deaths. Most countries including Sri Lanka have legislation banning smoking in indoor workplaces and public places. Certain public places such as entertainment venues continue to permit smoking. Particulate matter (PM2.5) is a widely accepted indicator to evaluate secondhand smoke levels. OBJECTIVE: To determine PM2.5 concentrations in selected public places (defined as a space which can be visited without permission) in Colombo, Sri Lanka. METHODS: Using convenient sampling technique, we measured PM2.5 concentration levels in four types of public places (restaurants: n=6; bars: n=6; cafes: n=4; pubs and entertainment venues: n=4) during January to March, 2009. A particulate matter monitor (Model AM510 - SIDEPAK Personal Aerosol Monitor) was used to measure indoor air quality for 40 minutes and the immediate outdoors for 10 minutes before and after the indoor measurement. RESULTS: The mean indoor PM2.5 concentration was 124.9 ug/m3 (SD± 81.0) [range 33 ug/m3 - 299 ug/m3; median, 97.0 ug/m3]. The mean outdoor PM2.5 concentration was 39.7 ug/m3 (±14.3) [range 18 ug/m - 83 ug/m3; median, 37.5 ug/m3]. Indoor to outdoor (I/O) PM2.5 ratio ranged from 1.1 to 14.9. The highest PM2.s concentration was recorded in a bar and the highest I/O ratio in an entertainment venue. Smoking density (number of burning cigarettes divided by volume of the public place) was not correlated with average indoor PM2.5 concentration (Pearson correlation = 0.36, p=0.12) or with I/O PM2.5 ratio (Pearson correlation = 0.07, p=0.76). The reported values are equal or above, compared to such venues in other countries. CONCLUSION: The authorities should take steps in enforcing the smoking ban in public places. Areas where smoking is permitted, proper ventilation should be ensured.en_US
dc.language.isoen_USen_US
dc.publisherCollege of Community Physicians of Sri Lankaen_US
dc.subjectAir Pollutionen_US
dc.subjectTobacco Smoke Pollutionen
dc.titleFine particle air pollution due to secondhand smoke in selected public places in Colomboen_US
dc.typeConference Abstracten_US
Appears in Collections:Conference Papers

Files in This Item:
File Description SizeFormat 
OP25.pdf12.85 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.