Please use this identifier to cite or link to this item: http://repository.kln.ac.lk/handle/123456789/21955
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWadasinghe, D.
dc.contributor.authorWarnakulasuriya, T.
dc.contributor.authorMedagoda, K.
dc.contributor.authorKottahachchi, D.
dc.contributor.authorLuke, D.
dc.contributor.authorAriyawansa, J.
dc.contributor.authorRathnayake, P.
dc.contributor.authorDissanayake, T.
dc.contributor.authorde Silva, D.
dc.contributor.authorAmarasiri, L.
dc.contributor.authorDevanarayana, N.M.
dc.contributor.authorScheepers, P.
dc.date.accessioned2021-02-12T07:31:48Z
dc.date.available2021-02-12T07:31:48Z
dc.date.issued2020
dc.identifier.citationJournal of the Ceylon College of Physicians. 2020; 51(Supplement 1): 34.en_US
dc.identifier.issn2448-9514
dc.identifier.issn0379-802X
dc.identifier.urihttp://repository.kln.ac.lk/handle/123456789/21955
dc.descriptionPoster Presentation Abstract (PP11), College of Physicians Annual Conference 2020, 19th-21st November. Colombo, Sri Lanka.en_US
dc.description.abstractINTRODUCTION AND OBJECTIVES: The respiratory system is a target for effects from air pollutants, including vehicle emissions composed of volatile organic compounds (VOC), particulate matter and other noxious gasses. Our objective was to study the association between selected VOCs and lung function in a cohort of fuel handlers. METHOD: Forty-four fuel handlers (men) from the Gampaha district of Sri Lanka aged 19-65 years were selected using consecutive sampling with a group of 38 males matched by age, without occupational exposure to fuel recruited as controls. Spirometry was performed using a Vitalograph Alpha Touch spirometer, according to ATS guidelines. Pre and post shift VOC levels were measured in end exhaled air samples. RESULTS: The spirometry parameters were not significantly different between the two groups but obstructive (47.72% vs.34.21%) and restrictive ventilatory patterns (31.81% vs. 21.05%) were higher among the fuel handlers. FVC and FEV1 negatively correlated with age (r=-0.672, p<0.001 and r=-6.888, p<0.001 respectively) and number of days of exposure (r=-0.329, p=0.033 and r=-0.306, p=0.049 respectively). Among the fuel handler's, benzene exposure negatively correlated with FVC (r=-0.552, p=0.012) and FEV1 (r=-0.476, p=0.034) and toluene exposure negatively correlated with PEF (r=-0.488, p=0.034). Although levels of all VOCs measured were significantly low among the controls, toluene exposure levels negatively correlated with all spirometry parameters (p<0.05). CONCLUSIONS: A decline in lung function is seen with more days of exposure as a fuel handler. The different vVOCs· affect the volume parameters and flow parameters uniquely and even non-occupational exposure causes an alteration of spirometry parameters among adult males.en_US
dc.language.isoen_USen_US
dc.publisherJournal of the Ceylon College of Physiciansen_US
dc.subjectLung functionen_US
dc.titleLung function of fuel handlers exposed to volatile organic compoundsen_US
dc.typeConference abstracten_US
Appears in Collections:Conference Papers

Files in This Item:
File Description SizeFormat 
JCCP 6.pdf1.47 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.