Optimizing the efficiency of a probe-based duplex qPCR assay for accurate detection of normalized PI4KA gene copy number
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Faculty of Graduate Studies - University of Kelaniya, Sri Lanka.
Abstract
Quantitative PCR (qPCR) is a powerful molecular tool, and its capability to multiplex enhances its utility. However, multiplexing can reduce PCR efficiencies compared to monoplex reactions. This study aims to establish comparable PCR efficiencies for a probe-based duplex qPCR assay that quantifies PI4KA gene copy number relative to the reference gene SHANK3. Three standard curves were generated for two monoplex reactions and duplex assay with a 10-fold DNA dilution series (100 ng, 10 ng, 1 ng, and 0.1 ng) to evaluate the efficiencies in the PCR. All reactions were duplicated on the Bio-Rad CFX96 Touch™ system with previously optimized conditions. Reaction efficiencies were calculated as 10-1/slope−1 using the Bio-Rad CFX Maestro application. Each monoplex reaction demonstrated high efficiency (E=80%-110%) and a reliable correlation coefficient (R²≥0.98). However, in the duplex response, the efficiency of SHANK3 amplification was observed to be compromised (EPI4KA=108.5%, R2PI4KA=0.98, ESHANK3=149.5%, R2SHANK3=0.86). Thus, to enhance SHANK3 amplification in the duplex, primer concentrations for PI4KA (0.2-0.4 μM) were reduced relative to SHANK3 (0.4-0.8 μM) in various combinations. Based on the results, the primer concentrations that produced the lowest combination of Cq values, PI4KA Forward/Reverse 0.2 /0.2 μM (Cq=22.4+0.4) and SHANK3 Forward/Reverse 0.4 μM/0.8 μM (Cq=24.7+0.2) were selected for reconstructing the duplex PCR. The regenerated standard curve for the optimized duplex PCR showed amplification efficiencies of 98.6% (R2=0.99) for PI4KA and 99.4% (R2=0.90) for SHANK3. After the final optimization of the duplex PCR, the gene dose values obtained for the positive (i.e. PI4KA gene deleted; ≃0.5) and control (healthy; ≃1) samples confirmed their accuracy in detecting normalized gene doses. Although optimizing the PCR efficiency of the duplex qPCR provided a robust assay for detecting PI4KA copy number, further validation of the assay for precision and sensitivity is recommended before its clinical use.
Description
Citation
Tennakoon, T. M. O. D., Warsapperuma, N., Ranaweera, D. M., de Silva, D. C., Perera, N., & Galhena, G. H. (2024). Optimizing the efficiency of a probe-based duplex qPCR assay for accurate detection of normalized PI4KA gene copy number. International Postgraduate Research Conference (IPRC) - 2024. Faculty of Graduate Studies - University of Kelaniya, Sri Lanka. (p. 4).