Inter-rater variability of ultrasound scan measurement

No Thumbnail Available

Date

2010

Journal Title

Journal ISSN

Volume Title

Publisher

College of Community Physicians of Sri Lanka

Abstract

INTRODUCTION : To assess inter-rater variability of ultrasound scan measurements for determining period of gestation by three raters applying balanced incomplete block design. METHODOLOGY: Twelve pregnant women who attended the field antenatal clinics were subjected to scan measurements, in terms of bi-parietal diameter (BPD), femur length (FL), abdominal (AC) and head (HC) circumferences of the fetus between 15-24 weeks of gestation. Each pregnant woman was scanned by two of the three raters who were blind to the measurements made by the other using the same machine. Balanced incomplete block design was generated and data were analyzed using ANOVA. RESULTS: There were no statistically significant variation among raters in measuring BPD (F = 0.68; p = 0.53), AC (F = 1.99; P = 0.19) and HC (F = 0.06; p = 0.94). There was statistically significant variation among raters for measuring FL (F = 7.4; P = 0.01). CONCLUSION: Statistically significant inter-rater differences were observed only for measurements of FL. However, despite the inter-rater differences of mean abdominal and head circumferences being not significant statistically, their variance can have a clinical significance.

Description

Keywords

Citation

Journal of the College of Community Physicians of Sri Lanka. 2010; 15(1): pp.52-8

Endorsement

Review

Supplemented By

Referenced By